BL4-2 Hardware: X-ray Source

Structural Molecular Biology

Illuminating Biological Structures at the Atomic and Molecular Levels

SMB

NIH
Click here to learn about capabilities available at other BER Structural Biology and Imaging Resources.

Biological Small Angle X-ray Scattering/Diffraction

BL4-2 Hardware: X-ray Source

Based on a 2004 upgrade funded by the Department of Energy and the National Institutes of Health, SPEAR3 is a 3-GeV, high-brightness third generation storage ring typically operating at 500 mA beam current in top-off mode, during which the current is kept constant within 1% by injecting electrons into the ring every five minutes. The X-rays utilized by the different beamlines at SSRL are produced using insertion devices (wigglers and undulators) and bending dipole magnets of its accelerator, SPEAR3. 

BL4 Wiggler

Beamline 4 uses a 2300mm long, 20 pole (i.e. 230mm period), 2T wiggler insertion device from Danfysik as its X-ray source. The wiggler produces an intense beam of X-rays with a critical energy of 12.26 keV. The radiation fan emitted by the wiggler (with a half width of 8.5 mrad) provides X-rays for the three experimental end stations at beamline 4. The outer portions of the fan is utilized by the spectroscopy side stations BL4-1 and BL4-3, the central 1.25 mrad of the produced X-rays is providing an intense beam of synchrotron radiation for BL4-2. However, to improve the data in the low-q region typical operation of the beamline limits the horizontal acceptance to 0.5 mrad of the wiggler beam.  

BL4 wiggler installed in the SPEAR tunnel