BL10-2b

    Overview
    SPEAR3

    In Commissioning: In-situ, Multi-modal, Catalysis-centric X-ray Spectroscopy End-Station

    Beam line currently closed for upgrade.

    Beam line 10-2 is a wiggler-based source that splits time between the front hutch (BL10-2a), instrumented for wide-angle X-ray scattering, and the rear hutch (BL10-2b), instrumented for X-ray spectroscopy with a focus on in-situ, time-resolved catalyst characterization.

    The BL10-2b hutch is equipped with integrated systems for conducting in-situ/operando thermal-heterogeneous catalysis and electro-catalysis experiments with product analytics for time-resolved studies. An infrared spectrometer installed in the hutch allows for scheduling blocks focused on combined XAS/FTIR measurements probing the metal center as well as adsorbates and ligands. Spectra can be collected at rates up to 50 ms/XAS spectra using the quick-scanning mode of the monochromator.

    Sample Environment

    Room-temperature ex-situ sample stages
    Capillary-cell (RT-700°C, 1-21 bara)
    Two-chamber, flow-through electrochemical cell

    Instrumentation

    Detectors Parallel plate ionization chambers
    PIPS diode
    24-element Ge solid-state detector (Coming Winter 2023-Spring 2024)
    Bruker Vertex 70V
    Rear hutch Dual Sample Stages [statement about beam position on stage TBD]
    Process Control and Analytics Compressed gas hookups for ambient or high-pressure flow systems Two 6-gas flow systems with valving for modulation and vapor dosing experiments
    Portable 4-gas high pressure flow system
    [Pump details here]
    Biologic SP250 [check me] potentiostat
    Hiden Mass Spectrometer
    [GC specs here]
    Other Filter wheels for harmonic selection
    Automated reference changer

    Technical Specifications

    Energy

    Si(111) 4.7-22 keV
    Si(333) 14.1-30 keV

    Optics

    M0 Mirror Monochromator M2 Mirror
    Rh-coated cylinder mirror for harmonic rejection and vertical collimation. Cutoff-energies at 12.65, 17.4, 23.0 keV. Mirror removable for higher energy access. Si(111) liquid nitrogen cooled double crystal, non-fixed exit with quick scanning capabilities. Step-scanning, continuous scanning and quick-scanning (50 ms EXAFS) capable. Rh-coated toroid mirror for vertical and horizontal focus. Spot size approximately 200 um vertical x 500 um horizontal.

    Absorption

    508 μm Be, 4.4 m He, 205 μm fixed, 1016 μm graphite (insertable, user controlled)