Advances in accelerator technology and in the theoretical understanding of collective instabilities and production of coherent radiation, have been the driving forces of the progress toward brighter synchrotron radiation sources, with scientific applications developing in response to the availability of new sources. The rate of improvement in source capability has been tremendous: for 30 years x-ray source brightness has been increasing exponentially with a doubling time of about 10 months. A modern synchrotron source is eleven orders of magnitude brighter than a 1960s laboratory x-ray source. Seldom, if ever, in history (perhaps only in the field of visible laser optics and colliders for high energy physics) has a scientific discipline seen its tools change so dramatically within the active life of a single generation of scientists. Such change makes it very difficult to predict the future. No one foresaw the huge impact on biomedical research that has come from synchrotron-based EXAFS and protein crystallography, though these techniques had been developed previously using laboratory sources. The new source capability made them qualitatively and unexpectedly more powerful. This history indicates that it is very difficult to predict the eventual applications of the new Self-Amplified Spontaneous Emission Free-Electron Lasers (SASE FELs), a source more than ten orders of magnitude brighter than today’s synchrotron-based sources, and with a pulse duration of 100 to 1000 times shorter. We can, however, be confident that the X-ray SASE-FEL, by opening to our exploration a totally new range of physical parameters, will lead to new discoveries in many areas of physics, chemistry and biology.
In a SASE FEL, lasing is achieved when a high-brightness electron beam interacts with an intense beam of light while traveling through the periodic magnetic field of an undulator. Under the right conditions, a collective instability develops, and the electrons in the bunch, which are initially randomly distributed, acquire a longitudinal density modulation at the optical wavelength leading to coherent emission and to a large enhancement of radiation power. The net result is an exponential increase of radiated power. This increase will eventually saturate at power levels about seven orders of magnitude above conventional undulator radiation. The radiation pulses produced by the SASE FEL are of sub-picosecond duration and fully transversely coherent.
The development of SASE FELs at SLAC started ten years ago with the study of the Linac Coherent Light Source (LCLS) [1], following the development of the SASE theory in the preceding decade. The experimental demonstration of the SASE-FEL collective instability and the agreement between the experimental data and the theory was achieved in the late 90s, initially in an experiment at UCLA, followed by other experiments at Los Alamos and Brookhaven by a UCLA-SLAC-LANL-BNL collaboration. More recently, other experiments have been done at Argonne and DESY, extending the SASE-FEL operation to the UV region. Today, in addition to the LCLS project at SLAC, another x-ray SASE FEL facility is being developed at the DESY laboratory in Germany and a number of longer wavelength devices are being proposed at other locations worldwide.
Three long wavelength experiments have been carried out, recently, to verify that the ultra-high density electron beams needed for the LCLS can be generated, transported and manipulated, to further study the SASE FEL physics, and to verify that the SASE process does saturate at the predicted distance from the beginning of the undulator. One of them, the Visible to Infrared SASE Amplifier (VISA) experiment, a SLAC-BNL-LLNL-UCLA collaboration [2], was carried out in 2001 with major participation from SSRL.
Saturation occurs in a SASE FEL when the maximum gain possible, for a given parameter set, has been achieved. At saturation, shot-to-shot intensity fluctuations are reduced. The LCLS is being designed to operate in the saturation regime. The distance from the beginning of the undulator to the point at which saturation occurs as well as the per-pulse radiation energy at saturation have been predicted theoretically but had not been measured in an experiment until recently.
The VISA experiment, conducted at the Accelerator Test Facility (ATF) (Figure 2) of the Brookhaven National Laboratory (BNL) in New York, has studied the properties of the SASE FEL process in a saturating system. First evidence of saturation was observed on March 16, 2001. The experiment utilized a high brightness electron injector and a strong focusing 4-m long undulator. The design parameters are listed in Table 1. A saturated gain greater than 108, with an e-folding power gain length smaller than 19 cm, was observed at a radiation wavelength of 840 nm. Measurements of exponential gain, and of the intensity and the spectral and angular properties of the radiation have been carried out, and the results have been compared to theory and to start-to-end simulations of the injector, the beam transport, and the undulator system (Figure 3). High gain conditions were found to be critically dependent on compression of the electron beam during transport.
Wavelength(fundamental) | 800 nm |
---|---|
E-Beam Energy | 72 MeV |
Peak Current | 200 A |
Normalized Emittance | 2 mm – mrad |
Energy Spread | 0.17 % |
Power Gain Length | 18.5 cm |
Spot Size | 60mm |
The onset of FEL saturation after 7 orders of magnitude of gain was seen in the VISA experiment at about 3.6 m after the beginning of the undulator. The e-folding radiation power gain length, supported by 5 data points taken at 50-cm separation along the 4-m long undulator, was measured to be 18.5 cm. The wavelength of the radiation was 840 nm, i.e. in the Near Infrared spectral region. This is the second experiment that has shown SASE saturation. Saturation of a SASE FEL was first observed in September 2000 in Argonne at the Low Energy Undulator Test Line (LEUTL) FEL. Recently on September 10, 2001, the SASE FEL at the TESLA Test Facility (TTF) at the DESY laboratory in Hamburg, Germany, observed saturation at 98 nm wavelength.
The factor that makes the VISA experiment particularly significant is that its system requirements are very demanding and similar to those of the LCLS project, which is designed to operate in the spectral range of 0.15 to 1.5 nm. For example, VISA requires strong quadrupole focusing, state-of-the-art alignment of the undulator segments, and high quality of the undulator magnetic field; characteristics all shared with the LCLS design.
One of the properties of a SASE FEL is the generation of nonlinear harmonics, which occurs only in the high gain and saturation regime. Both, simulation and theory predict the intensity of the 3rd harmonic to be about 1% of the fundamental for an x-ray SASE FEL. This is about 8 orders of magnitude brighter than current third generation synchrotron radiation sources. The radiation is transversely coherent and provides the possibility for SASE FELs to have broad spectral coverage, i.e., it will make sub-Angstrom radiation available from the LCLS. The spectrum of SASE radiation has been measured for the first time at the VISA experiment (see Figure 4). It confirms experimentally that high quality nonlinear harmonic spectra can be expected for future short wavelength SASE FELs driven by high-brightness electron beams.
The VISA team will continue the work through this year with a detailed study of the dependence of radiation parameters on electron beam quality.
- “Linac Coherent Light Source (LCLS) Conceptual Design Report,” SLAC-R-593, UC-414 (April 2002). http://ssrl.slac.stanford.edu/lcls/CDR/
- A. Tremaine, X. J. Wang, M. Babzien, I. Ben-Zvi, M. Cornacchia, H.-D. Nuhn, R. Malone, A. Murokh, C. Pellegrini, S. Reiche, J. Rosenzweig, and V. Yakimenko,“Experimental Characterization of Nonlinear Harmonic Radiation from a Visible Self-Amplified Spontaneous Emission Free-Electron Laser at Saturation.,” Phys. Rev. Lett. 88, 204801 (2002)
- L. M. Young, J. H. Billen, “Parmela”, LA-UR-96-1835, Rev, January 8, 2000.
- M. Borland, “Elegant: A Flexible SDDS-Compliant Code for Accelerator Simulation”, ICAP-2000, Darmstadt, Germany, September 2000.
- S. Reiche, Nucl. Instr. Meth. A429, 243 (1999).