EXPERIMENTAL STATION 8-2 |
| CURRENT STATUS: | Open | ||||||||||||||
| SUPPORTED TECHNIQUES: |
X-ray absorption spectroscopy, near edge
Photoemission spectroscopy | ||||||||||||||
| MAIN SCIENTIFIC DISCIPLINES: | Materials | ||||||||||||||
| % TIME GENERAL USE: | 100% | ||||||||||||||
| SCHEDULING: | Proposal Submittal and Scheduling Procedures Current SPEAR and Beam Line Schedules |
||||||||||||||
| SOURCE: | Bending magnet station (soft x-ray) | ||||||||||||||
BEAM LINE SPECIFICATIONS:
|
|||||||||||||||
| OPTICS: | M0 mirror: toroidal SiC | ||||||||||||||
| MONOCHROMATOR: |
6m spherical grating monochromator (TGM) Grating Monochromator References Monochromator Crystal Glitch Library Crystal changes need to be scheduled and coordinated in advance with BL support staff. |
||||||||||||||
| ABSORPTION: | NA | ||||||||||||||
| INSTRUMENTATION: | User Chambers on VUV Lines | ||||||||||||||
| DATA ACQUISITION AND ANALYSIS: |
Data Aquisition: XAS-Collect used for XAS spectra.
Photoemission spectra are collected by electron energy analyzers installed on UHV chambers. Software Super (installed on the beam line computer) can be used to control standard PHI CMA ananlyzers.
Data Analysis: EXAFSPAK for XAS spectra. Core level photoemission peak fitting can be performed using any XPS peak fitting procedures. See simple (free) fitting program called XPSPEAK at http://www.phy.cuhk.edu.hk/~surface/XPSPEAK/ X-ray Data Booklet |
||||||||||||||
| RESPONSIBLE STAFF: | Dan Brehmer,
650-926-3015
Dennis Nordlund, 650-926-3112 |
||||||||||||||
| BEAM LINE PHONE NUMBER: | 650-926-5282 On-site Users: Contact the Duty Operator at 9-926-4040 | ||||||||||||||
| GENERAL DESCRIPTION: |
BL8-2 can be used to probe a wide range of core levels using photoemission and X-ray absroption spectroscopy. See video on the role of aluminum foil in vacuum chamber 'bakeouts.' |
||||||||||||||
| Sample Preparation Labs: | The SSRL Structural Molecular Biology (SMB) Sample Preparation Laboratories are available to users by prearrangement. To use a laboratory, users must complete laboratory training, and provide a list of all chemicals to be brought, used or stored in the Sample Preparation Laboratory. For details, contact Cynthia Patty (650-926-3925). | ||||||||||||||
| SCIENTIFIC APPLICATIONS /
SELECTED RESULTS: |
K. Glenn Tirsell and V.P. Karpenko, "A
General Purpose Sub-keV X-ray Facility at the Stanford Synchrotron Radiation
Laboratory", Nucl. Instrum. & Methods A291, 511-517 (1990)
| ||||||||||||||
| ENGINEERING NOTES: |
http://www-ssrl.slac.stanford.edu/safety/beamlines/bl8/ |
||||||||||||||
| SSRL | Beamlines | User Admin | Safety |
| Last Updated: | 22 APR 2008 |
| Content Owner: | Dan Brehmer |
| Page Editor: | Nikola Stojanovic |